ASG

Configuration Code:
RLB2GVDF2S
Description:
202 GGT BP-D REG

Low Pressure Back Pressure Regulators control pressure upstream of your production vessel and feature lower set point options than the standard Back Pressure Regulator.

These valves are classified as intermittent venting (non-bleed), and meet most producer's emissions standards.

Utilizes process gas to operate integrated pilot. Gas must be clean and dry.

Build & Save a Quote

We'll get you options, pricing, and anything else you need.

Helpful Face

Anything we can do to help?

Talk to a specialist at (405) 525-4298 or fill out a quick product message form.

Need Service?

Our certified technicians work closely with our engineering and product design teams.

They have direct access to the most up-to-date product information.

Request Service

Repairs & Maintenance

Browse our Accessories and our Repair Kits to keep your Kimray product in peak condition.

We recently consolidated our regulator repair kits. Please see the related product notice for a full cross-reference table.

Product Applications

Applications Image
Zoom in on interactive diagrams.

Product Charts

1 of 1: Flow Coefficient (Cv) at Stem Travel (% Open)
10%
4
20%
6.2
30%
8.6
40%
12.1
50%
17.2
60%
23.5
70%
30.4
80%
36.3
90%
42.5
100%
47

Tech Specs

Type Value
Connection Size: 2 "
Connection Type: Grooved
Body Style: Through Body
Body Material: Cast Ductile
NACE MR0175: Option Available
Trim Size: 2 "
Trim Type: Equal Percentage
Leakage Class: Class VI
Process Fluid: Gas
Pilot Type: Vent
Max Working Pressure: 300 psig
Min Set Point Pressure: 5 psig
Max Set Point Pressure: 20 psig
Operation: Pneumatic
Face-to-Face Length: 8.75 "
Min Cv: 6.2
Max Cv: 47
Cf: 0.84