AET5

Configuration Code:
RFB4ARDR1S
Description:
418 FGT LBP5-D REG

For controlling liquid, gas, or a mixture of both. Outside supply of gas or air required.

Outside Supply of clean/dry gas or air required.

Build & Save a Quote

We'll get you options, pricing, and anything else you need.

Helpful Face

Anything we can do to help?

Talk to a specialist at (405) 525-4298 or fill out a quick product message form.

Need Service?

Our certified technicians work closely with our engineering and product design teams. They have direct access to the most up-to-date product information.

Request Service

Repairs & Maintenance

Browse our Accessories and our Repair Kits to keep your Kimray product in peak condition.

Product Charts

1 of 1: Flow Coefficient (Cv) at Stem Travel (% Open)
10%
4.7
20%
7.3
30%
10.1
40%
14.2
50%
20.2
60%
27.5
70%
35.6
80%
42.5
90%
49.7
100%
55

Tech Specs

Type Value
Connection Size: 4 "
Connection Type: 150 RF
Body Style: Through Body
Body Material: Cast Ductile
NACE MR0175: Option Available
Trim Size: 2 "
Trim Type: Equal Percentage
Leakage Class: Class VI
Process Fluid: Liquid and Gas
Pilot Type: Vent
Max Working Pressure: 250 psig
Min Set Point Pressure: 10 psig
Max Set Point Pressure: 250 psig
Operation: Pneumatic
Catalog Page: 06:40.1
Face-to-Face Length: 15.06 "
Min Cv: 7.3
Max Cv: 55