4"
150 RF
Through Body
4" Equal Percentage Trim
4" Equal Percentage Trim
Cv @ % Stem Travel (%open) | |||||||||
---|---|---|---|---|---|---|---|---|---|
10% | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | 100% |
17.8 | 27.9 | 38.6 | 54.2 | 77 | 105.2 | 135.9 | 162.2 | 189.8 | 210 |
Critical Flow Factor Cf = 0.75
Calculate Gas Flow RateControl pressure upstream of the valve by adjusting the set point to the desired max upstream pressure. Used on separators, heater treaters, compressor stations, and gas gathering systems.
Utilizes process gas to operate integrated pilot. Gas must be clean and dry.
Specifications
- Connection Size: 4 "
- Connection Type: 150 RF
- Body Style: Through Body
- Body Material: Cast Ductile
- Option Available for NACE MR0175 compliance or certification.
- Trim Size: 4 "
- Trim Type: Equal Percentage
- Seal Class: Class VI
- Process Fluid: Gas
- Pilot Type: Vent
- Max. Working Pressure: 250 psig
- Min. Set Point Pressure: 10 psig
- Max. Set Point Pressure: 250 psig
- Operation: Pneumatic
- Catalog Page: A:10.3
- Face-to-Face Length: 15 "
- Repair Kit P/N: RDI