Loading ...

3" Female NPT Through Body
1.625" Equal Percentage Trim

Process Fluid: Gas
Operation: Pneumatic
Pilot Type: Vent

Options Included In This Model:


Cv @ % Stem Travel (%open)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
2.9 4.5 6.2 8.8 12.5 17 22 26.3 30.7 34


Critical Flow Factor Cf = 0.82

Calculate Gas Flow Rate

Control pressure downstream of the valve by adjusting the set point to the desired max downstream pressure. Commonly used as a suction control valve on compressors.

Utilizes process gas to operate integrated pilot. Gas must be clean and dry.

Specifications

  • Connection Size: 3 "
  • Connection Type: Female NPT
  • Body Style: Through Body
  • Body Material: Cast Ductile
  • Option Available for NACE MR0175 compliance or certification.
  • Trim Size: 1.625 "
  • Trim Type: Equal Percentage
  • Seal Class: Class VI
  • Process Fluid: Gas
  • Pilot Type: Vent
  • Max. Working Pressure: 300 psig
  • Min. Set Point Pressure: 10 psig
  • Max. Set Point Pressure: 300 psig
  • Operation: Pneumatic
  • Catalog Page: BL_A07295
  • Face-to-Face Length: 12.06 "

Downloadable Documents


Tech Specs
Installation Operation & Maintenance Guide

Downloadable Models


Solidworks Model
STEP Model
DXF Model