Applications Image
View this product on application diagrams

ECPS6

Configuration Code:
CVS2S2TW16LKC
Description:
2200 SMT PO 1 IN S6

Build & Save a Quote

We'll get you options, pricing, and anything else you need.

Helpful Face

Anything we can do to help?

Talk to a specialist at (405) 525-4298 or fill out a quick product message form.

Product Charts

1 of 1: Flow Coefficient (Cv) at Stem Travel (% Open)
10%
2.8
20%
7
30%
11
40%
15
50%
18
60%
19
70%
20
80%
21
90%
21
100%
21

Tech Specs

Type Value
Connection Size: 2 "
Connection Type: Female NPT
Body Style: Through Body
Body Material: Steel
NACE MR0175: Compliant
Trim Size: 1 "
Trim Type: Linear (Nominal)
Trim Material: Stainless Steel
Leakage Class: Class IV
Process Fluid: Liquid and Gas
Max Working Pressure: 2000 psig
Actuator Spring Nominal Pressure: 20 psig
Max Supply Gas Pressure: 45 psig
Fail Position: Closed - Field Reversible
Operation: Pneumatic
Catalog Page: 01:10.1
Face-to-Face Length: 6.593 "
Min Cv: 7
Max Cv: 21
Cf: 0.77

Product Training

Learning Path

Check out our learning paths for product videos, step-by-step repair guides, troubleshooting tips, and more.

Start Learning Path

Product Videos

Compatible Kits and Tools

Type Product Code
Repair Kit: RFE + ADD TO QUOTE
Trim Set: T2899SS6

Frequently Asked Questions

Why would I choose a Stem Guided High Pressure Control Valve over a Cage Guided?

The Stem Guided High Pressure Control Valve has smaller trim sizes (available in 1" and 2" end connections) for smaller valve coefficients (Cv) compared to the Cage Guided series. "Stem Guided" refers to the stem itself guiding the trim into its seat.

Stem Guided High Pressure Control Valve is a non-balanced valve that can be used as a dump valve, pressure regulator, suction controller, recirculation valve, as well as in plunger lift or flowback applications

Yes, you will also find the T-Body model helpful if you are experiencing erosion in your valve's body.

High Pressure Control Valves (HPCV) is a versatile product that can be used in pressure control and flow control. 

We offer a sizing calculator on our website that can help. By inputting your specific operating conditions, the calculator will determine the appropriate size for your High Pressure Control Valve.

Yes. The highest pressure rated High Pressure Control Valve is 6,000 psig. It is important to understand the pressure limitations when selecting the appropriate High Pressure Control Valve.

Still have a question? Send us a quick product message to get help from our team.