Loading ...

DAC

36 FWA TREATER VAL

Most Popular

Treater Valve

3" 150 RF Angled Body
3" Linear (Nominal) Trim

Process Fluid: Liquid and Gas
Operation: Weight-Operated

Options Included In This Model:


100% Cv = 93.30

Critical Flow Factor Cf = 0.75

Calculate Liquid Flow Rate

Ideal for emissions-free level control in heater treaters and salt water disposal systems, this valve actuates based on the hydrostatic pressure generated from the column of liquid in the discharge piping from the vessel. The height of water column can be field adjusted by moving the weight on the arm in or out. Operates on liquid head height from 2 ft to 4 ft, with options up to 12 ft.

Specifications

  • Connection Size: 3 "
  • Connection Type: 150 RF
  • Body Style: Angled Body
  • Body Material: Cast Ductile
  • Option Available for NACE MR0175 compliance or certification.
  • Trim Size: 3 "
  • Trim Type: Linear (Nominal)
  • Seal Class: Class VI
  • Process Fluid: Liquid and Gas
  • Max. Working Pressure: 125 psig
  • Operation: Weight-Operated
  • Catalog Page: D:10.2
  • Repair Kit P/N: REM

Downloadable Documents


Tech Specs
Installation Operation & Maintenance Guide

Downloadable Models


Solidworks Model
STEP Model
DXF Model

Request Model