ACW5

Configuration Code:
RDP2ARDR1S
Description:
218 FGT PD5-D

Differential Pressure Regulators are used to maintain a constant pressure drop across the valve.

These valves are classified as intermittent venting (non-bleed), and meet most producer's emissions standards.

Utilizes process gas to operate integrated pilot. Gas must be clean and dry.

Build & Save a Quote

We'll get you options, pricing, and anything else you need.

Helpful Face

Anything we can do to help?

Talk to a specialist at (405) 525-4298 or fill out a quick product message form.

Need Service?

Our certified technicians work closely with our engineering and product design teams.

They have direct access to the most up-to-date product information.

Request Service

Repairs & Maintenance

Browse our Accessories and our Repair Kits to keep your Kimray product in peak condition.

We recently consolidated our regulator repair kits. Please see the related product notice for a full cross-reference table.

Product Applications

Applications Image
Zoom in on interactive diagrams.

Product Charts

1 of 1: Flow Coefficient (Cv) at Stem Travel (% Open)
10%
1.8
20%
2.8
30%
3.9
40%
5.4
50%
7.7
60%
10.5
70%
13.6
80%
16.2
90%
19
100%
21

Tech Specs

Type Value
Connection Size: 2 "
Connection Type: 150 RF
Body Style: Through Body
Body Material: Cast Ductile
NACE MR0175: Option Available
Trim Size: 1.25 "
Trim Type: Equal Percentage
Leakage Class: Class VI
Process Fluid: Gas
Pilot Type: Vent
Max Working Pressure: 250 psig
Min Set Point Pressure: 10 psig
Max Set Point Pressure: 250 psig
Operation: Pneumatic
Catalog Page: 06:80.1
Face-to-Face Length: 9 "
Min Cv: 2.8
Max Cv: 21
Cf: 0.75