Loading ...

MCS

3 FMVT 600RF PB 2 IV

Metering Valve

Piston Balanced
3" 600 RF Through Body
2" Equal Percentage Trim

Process Fluid: Liquid and Gas
Operation: Manual

Options Included In This Model:


Cv @ % Stem Travel (%open)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
2.9 4.9 7.4 9.5 12 17.4 28.9 40.8 48.1 52.6


Critical Flow Factor Cf = 0.75

Calculate Gas Flow Rate Calculate Liquid Flow Rate

Can be used to meter or control flow of liquids and/or gases on meter runs or flow lines. It can be used as a choke under low pressure drop conditions where freezing is not a problem. Used any time a reference control point is required in 64ths of an inch opening.

Specifications

  • Connection Size: 3 "
  • Connection Type: 600 RF
  • Body Style: Through Body
  • Body Material: Steel
  • Option Available for NACE MR0175 compliance or certification.
  • Trim Size: 2 "
  • Trim Type: Equal Percentage
  • Seal Class: Class VI
  • Process Fluid: Liquid and Gas
  • Max. Working Pressure: 1480 psig
  • Operation: Manual
  • Catalog Page: E1:55.3
  • Face-to-Face Length: 13.25 "
  • Repair Kit P/N: RSO

Downloadable Documents


Tech Specs
Tech Specs

Downloadable Models


Sorry, there are no available models for download at this time.


Request Model