This product notice is to inform you that Kimray is now offering Master Kits for regulators.
Kimray has many different models and orientations of regulators. As a legacy product family that has developed over time, Kimray has typically offered a unique repair kit to accompany each new model.
The new Master Kits for regulators add value by creating more inventory versatility, as well as simplifying the repair kit identification and order process for our customers.
Rather than offering a repair kit for most unique models, Kimray will now offer fewer kit types that will support a wider variety of regulator models – these options are:
- Standard Regulator Master Kit
This kit type will cover both steel and ductile versions of the following models (Full & Reduced Port): BP, BN, BV, FB, PR, PN, FR, PB, PN, DP - Non-Lube Regulator Master Kit
This kit type will cover both steel and ductile versions of the following models with Non-Lube (Full & Reduced Port): BP, BN, BV, FB, PR, PN, FR, PB, PN, DP, PA - Low Pressure Regulator Master Kit
This kit type will cover both steel and ductile versions of the following models (Full & Reduced Port): LB, VB, AB, LR, VR - Spring Loaded Regulator Master Kit
This kit type will cover both steel and ductile versions of the following models (Full & Reduced Port): SB
Order Codes by Type and Size
1" | 2" | 3" | 4" | 6" | |
---|---|---|---|---|---|
Standard Master Kit | RYD | RYG | RYK | RYO | RYRE |
Non-Lube Master Kit | RYE | RYH | RYL | RYP | RYS |
Low Pressure Master Kit | RYF | RYI | RYM | RYQ | RYT |
Spring Loaded Master Kit | - | RYJ | RYN | - | - |
Regulator Model Key
- BP = Back Pressure
- BN = Back Pressure Non-Vent
- BV = Back Pressure Vacuum
- FB = Back Pressure Outside Supply
- PR = Pressure Reducing
- RN = Pressure Reducing Non-Vent
- FR = Pressure Reducing Outside Supply
- RB = Pressure Reducing Balanced
- PN = Pressure Reducing Balanced Non-Vent
- DP = Differential Pressure
- PA = Pneumatically Adjusted
- LB = Low Pressure Back Pressure
- VB = Low Pressure Back Pressure Vacuum
- AB = Low Pressure Back Pressure Atmosphere
- LR = Low Pressure Pressure Reducing
- VR = Low Pressure Pressure Reducing Vacuum
- SB = Spring Loaded Back Pressure
Kit Equivalents
New Kit | Kits Replaced |
---|---|
RYD (1" Ductile Master Kit) | RRU RYA RBB |
RYE (1" Steel & NL Master Kit) | RBP RRUNL |
RYF (1" Ounces Master Kit) | RRYD RULD |
RYG (2" Ductile & Steel Master Kit) | RDG RRM RPK RBC RAE RRQ RBY C-RAE |
RYH (2" PNU & NL Master Kit) | RDGNL RRM-PNU |
RYI (2" Ounces Master Kit) | RUID RBGD RUAD RUED |
RYJ (2" SLBP Master Kit) | RNU1 RTB1 RNP RTC1 |
RYK (3" Ductile & Steel Master Kit) | RDH RRN RPL RBD RAF RRR RBZ C-RAF C-RBZ |
RYL (3" PNU & NL Master Kit) | RDHNL RRN-PNU |
RYM (3" Ounces Master Kit) | RUJD RBHD RUBD RUFD |
RYN (3" SLBP Master Kit) | RTD RTD1 RTD2 |
RYO (4" Ductile & Steel Master Kit) | RDI RRO RPM RBE RAG RRS RCA C-RAG C-RCA |
RYP (4" PNU & NL Master Kit) | RDINL RRO-PNU |
RYQ (4" Ounces Master Kit) | RUKD RBID RUCD RUGD |
RYR (6" Ductile & Steel Master Kit) | RDJ RRP RPN RBF RAH RRX RBW |
RYS (6" PNU & NL Master Kit) | RDJNL RRP-PNU |
RYT (6" Ounces Master Kit) | RYTD RBKD RUDD RUHD |