In this guide we’ll walk you through everything there is to know about low pressure control valves.
From the basics of how it works to step-by-step repairs and troubleshooting, you’ll gain a solid foundation of knowledge on how to operate and maintain Kimray’s low pressure control valves.
Use the table of contents to skip to different sections of the learning path.
1. How an Electric Low Pressure Control Valve (E-LO) Works
The Electric Low Pressure Control Valve (E-LO) is a durable, smart, cost-effective low pressure control valve. In this video, Product Manager Alex Crow demonstrates how the valve works.
The E-LO control valve is a low power, low pressure controller, and because it’s made with a standard Kimray body and seat it can flow any media that you normally find in natural gas or oil production.
Inside an Electric Low Pressure Control Valve (E-LO)
Inside the E-LO’s cover is the master control board. This is where your module connects. If you want to use a different module, you simply snap the old one out and snap the new one in.
You will also see a 4-pin connector with the Voltage In and Ground on the board itself, as well as a proof-of-closure connection. This is for discrete output to an LED or an auxiliary alarm to let you know it’s seated.
When you initially power up the valve, the motor will drive the seat completely closed, and you’ll get an LED indication of that closure.
You can also test the actuation of the valve with the button for on/off control. When the motor is running to open the valve, you will see a green LED indication. And when it closes you will see a red LED indication. It takes about four seconds fully open and two seconds to close.
Control Boards for the Electric Low Pressure Control Valve (E-LO)
The E-LO is an electric low pressure control valve designed to control flow in applications less than 45 psi. It features a modular control board, and we offer three different modules for the board:
Discrete module, which uses dry contacts only, less than three volts
Analog module, which is 4-20 milliamps for variable control
Modbus control module for Modbus RS-485
Applications for the Electric Low Pressure Control Valve (E-LO)
The E-LO can be used as a dump valve, a burner control valve, or for any type of flow control under 45 psi.
Each one of the pneumatic low pressure control valves might be named something slightly different depending on the technical document you're looking at.
The language I've always used is single, double, and adjustable double acting. Single acting could be called reverse, double acting is sometimes known as direct, and adjustable double acting is sometimes known as adjustable direct. Just keep that in mind, but I always use the single, double, and adjustable double acting language.
You would use this in applications where you want a fail-open valve or any time there is a pneumatic signal to the valve. You want that valve to be in the closed position. The pneumatic signal goes to the top of the valve actuator, and that pressure will hold the valve in the closed position.
By low pressure, I mean below 300 PSI. Normally, these first three products we're going to talk about are used in even lower pressures than that, usually below 30 PSI going through these valves. It's important to keep in mind that the operating pressure or the pressure inside of the valve cannot be more than double your supply pressure because the area of the actuator is twice that of the valve seat.
2.3 Single Acting Surface Area
For example, let's say we have 10 PSI in the valve body. That means you need at least five pounds of pneumatic pressure to hold that valve in the closed position. If you had 20 lbs of pressure in the valve body going from upstream to downstream and only 5 PSI of pneumatic signal, that valve would not seal properly. With the single acting, you just need to make sure that your supply pressure is sufficient to hold that valve in the closed position. A possible cause for a leaking valve could be that your pneumatic signal is not strong enough to hold it in the closed position.
The single-acting valve should operate well for a long time as long as you don't have any acid gases like H2S or CO2, which can deteriorate the elastomers in the valve and cause premature failure. If you have those types of acid gases, make sure you're using the appropriate elastomer that will stand up to those conditions.
2.4 Single Acting vs Double Acting
The single-acting valve is called single-acting because there is a single force put against this valve in comparison with the ones with the springs. There is one force on one side of the diaphragm, which is the pneumatic signal pushing it to a certain position.
This valve has a pneumatic signal that comes underneath the diaphragm, and it also has a spring on the opposite side of that diaphragm. There are two forces acting against one another, which is why we call it a double-acting valve.
You can use this valve in gas or liquid applications. The pneumatic signal coming to this valve could be from some kind of pilot, like a temperature controller, or a liquid level controller or switch. It just needs that pneumatic signal to actuate the valve.
In the rendering here, pressure opens the valve, and the valve spring makes it a fail-closed valve. Without a pneumatic signal on this valve, the spring would then force it closed.
There are a few different spring options for these valves, so depending on your operating pressure, you want to make sure you have the appropriate spring inside this valve. This way, it can close against that upstream pressure, whether you're operating on relatively low pressure like below 5 or 6 PSI, or up to 35 PSI. You want to make sure you have the correct spring in there.
The single acting is more or less fail-open because if you remove that pneumatic signal, the upstream pressure is going to push the valve open. If you want the failure position of the valve to be open, or you want the valve to remain closed as long as it has a pneumatic signal, go with a single-acting valve.
2.6 Fail Open vs Fail Closed
If you want the failure position to be closed, go with the double-acting valve because it has a spring in the actuator that will force it closed without a pneumatic signal.
For example, the double-acting valve can be used in burner valve applications. You might have a T12 thermostat monitoring vessel temperature, and when it gets below its set point, you need the vessel to heat back up. The output from the T12 goes to the burner valve, a low pressure control valve.
The pneumatic signal opens the burner valve, allowing fuel to go to the burner to increase the temperature. The T12 itself is indirect acting in that application, and it’s going to a double-acting burner valve, opening it up to allow the fuel through.
Adjustable Double Acting Low Pressure Control Valve
2.7 Adjustable Double Acting Low Pressure Control Valve
The reason you might need an Adjustable Double Acting Low Pressure Control Valve is that you want the valve to have a failure position of closed, but you don't want to swap out springs. You want to change the spring tension or range without taking apart the valve.
This valve has an adjustment screw on top, so you can increase or decrease the spring tension, which will hold against different upstream pressures. It also allows you to turn this valve into a spring-loaded back pressure valve in some applications where you don't have to have a pneumatic signal going to the valve actuator. The spring on top acts against the upstream pressure pushing up on the seat.
This is a 1-inch valve that can be used in either liquid or gas applications. Most commonly, it's used in BMS (burner management systems) to control the fuel going to a burner electronically. This allows you to automate your system if you're doing remote startups or shutdowns. You can also remotely monitor this valve. It has the same capabilities as its pneumatic counterparts but operates electrically.
2.9 E-LO Circuit Boards
The E-LO valve has a small electric actuator on top and uses a 4 to 20 milliamp signal or a discrete signal for on/off control. A 4-20 signal is modulating and analog, like a dimmer on a light switch where you can go between on and off.
Discrete signals are like a light switch where it's either on (valve opening) or off (valve closing).
There is also an optional Modbus card you can get for the E-LO, but it is an extra piece you have to order.
Emissions Options
One of the big reasons people use the E-LO valve instead of a pneumatic valve is for emissions and emissions reduction. This valve uses electricity to actuate, so there is no vented gas and no potential for vented gas. With the low pressure pneumatic control valves, the only options to make them emissions-free would be to use nitrogen or compressed air instead of gas.
2.10 Emissions Free Options
The products themselves do not vent, but the pneumatic signal is vented back through the pilot. If you supply that pilot with nitrogen, it sends the nitrogen to the valve, and the signal is vented back through the pilot. If it's nitrogen, you're emissions-free.
The reason we don't use compressed air with any of these pneumatic low pressure control valves is that there's only one point of failure between the oxygen in your compressed air and the flow stream. If the diaphragm or the O-ring fails, you have the potential to mix both oxygen and fuel, needing only heat or a spark to cause combustion.
2.11 Importance of Using High Pressure Control Valve vs Low Pressure Control Valve
If you want to move towards compressed air to reduce emissions, you can in a burner valve application. We suggest going to a High Pressure Control Valve. You can still get small CVs or small flow rates that fit a wide application, but the valve actuator and the process flow are separated by an open yoke.
Even if the diaphragm where the compressed air is sent fails, the air is vented to the atmosphere and not introduced into the flow stream of the process. This way, you won't have oxygen and fuel mixing.