Loading ...

Stem Guided Non-Balanced
1" Female NPT Through Body
0.125" Equal Percentage Trim

Process Fluid: Gas
Operation: Pneumatic
Pilot Type: Vent

Options Included In This Model:

  • Valve Fail Position: Closed

Cv @ % Stem Travel (%open)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
0.01 0.02 0.03 0.04 0.06 0.09 0.15 0.26 0.32 0.34


Critical Flow Factor Cf = 0.73

Calculate Gas Flow Rate

Control pressure downstream of the valve by adjusting the set point to the desired max downstream pressure. Commonly used as a suction control valve on compressors.

Utilizes process gas to operate integrated pilot. Gas must be clean and dry.

Specifications

  • Connection Size: 1 "
  • Connection Type: Female NPT
  • Body Style: Through Body
  • Body Material: Steel
  • Option Available for NACE MR0175 compliance or certification.
  • Trim Size: 0.125 "
  • Trim Type: Equal Percentage
  • Seal Class: Class IV
  • Process Fluid: Gas
  • Pilot Type: Vent
  • Max. Working Pressure: 4000 psig
  • Min. Set Point Pressure: 1 psig
  • Max. Set Point Pressure: 20 psig
  • Valve Fail Position: Closed
  • Operation: Pneumatic
  • Catalog Page: E1:10.2
  • Face-to-Face Length: 4.44 "

Downloadable Documents


Tech Specs
Installation Operation & Maintenance Guide

Downloadable Models


Sorry, there are no available models for download at this time.