Loading ...

AAG5

412 FGT BP5 REGULATOR

Discontinued
4" 150 RF Through Body
2" Equal Percentage Trim

Process Fluid: Gas
Operation: Pneumatic
Pilot Type: Vent

Options Included In This Model:


AAG
Cv @ % Stem Travel (%open)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
4.7 7.3 10.1 14.2 20.2 27.5 35.6 42.5 49.7 55


Critical Flow Factor Cf = 0.8

Utilizes process gas to operate integrated pilot. Gas must be clean and dry.

Specifications

  • Connection Size: 4 "
  • Connection Type: 150 RF
  • Body Style: Through Body
  • Body Material: Cast Ductile
  • Option Available for NACE MR0175 compliance or certification.
  • Trim Size: 2 "
  • Trim Type: Equal Percentage
  • Seal Class: Class VI
  • Process Fluid: Gas
  • Pilot Type: Vent
  • Max. Working Pressure: 175 psig
  • Min. Set Point Pressure: 5 psig
  • Max. Set Point Pressure: 125 psig
  • Operation: Pneumatic
  • Catalog Page: A:10.3
  • Face-to-Face Length: 15 "

Downloadable Documents


Tech Specs
Installation Operation & Maintenance Guide

Downloadable Models


Solidworks Model
STEP Model

Request Model