Loading ...

1" Female NPT Through Body
1" Equal Percentage Trim

Process Fluid: Gas
Operation: Pneumatic
Pilot Type: Non Vent

Options Included In This Model:


Cv @ % Stem Travel (%open)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
1.1 1.8 2.4 3.4 4.8 6.6 8.5 10.2 11.9 13.2


Critical Flow Factor Cf = 0.74

Calculate Gas Flow Rate

Control pressure downstream of the valve by adjusting the set point to the desired max downstream pressure. Commonly used as a suction control valve on compressors.

Utilizes process gas to operate integrated pilot. Gas must be clean and dry.

Specifications

  • Connection Size: 1 "
  • Connection Type: Female NPT
  • Body Style: Through Body
  • Body Material: Steel
  • Option Available for NACE MR0175 compliance or certification.
  • Trim Size: 1 "
  • Trim Type: Equal Percentage
  • Seal Class: Class VI
  • Process Fluid: Gas
  • Pilot Type: Non Vent
  • Max. Working Pressure: 300 psig
  • Min. Set Point Pressure: 10 psig
  • Max. Set Point Pressure: 300 psig
  • Min. Differential Pressure: 5 psi
  • Operation: Pneumatic
  • Catalog Page: A:25.3
  • Face-to-Face Length: 4.38 "

Downloadable Documents


Tech Specs
Installation Operation & Maintenance Guide

Downloadable Models


Sorry, there are no available models for download at this time.


Request Model